7 changes: 7 additions & 0 deletions bundles/org.openhab.binding.nibeheatpump/README.md
Original file line number Diff line number Diff line change
Expand Up @@ -800,6 +800,10 @@ This binding currently supports following channels for F1x45 pump models:
| 47370 | Switch | 0 | 1 | Setting | Allow Additive Heating | |
| 47371 | Switch | 0 | 1 | Setting | Allow Heating | |
| 47372 | Switch | 0 | 1 | Setting | Allow Cooling | |
| 47374 | Number | -200 | 400 | Setting | Start Temperature Cooling | |
| 47375 | Number | -200 | 400 | Setting | Stop Temperature Heating | |
| 47376 | Number | -250 | 400 | Setting | Stop Temperature Additive | |
| 47377 | Number | 0 | 48 | Setting | Outdoor Filter Time | |
| 47378 | Number | 10 | 250 | Setting | Max diff. comp. | |
| 47379 | Number | 10 | 240 | Setting | Max diff. add. | |
| 47380 | Switch | 0 | 1 | Setting | Low brine out autoreset | |
Expand Down Expand Up @@ -835,6 +839,9 @@ This binding currently supports following channels for F1x45 pump models:
| 47540 | Number | 10 | 2000 | Setting | Heat DM diff | |
| 47543 | Number | 10 | 150 | Setting | Cooling DM diff | |
| 47570 | String | 0 | 255 | Setting | Operational mode | 0=Auto, 1=Manual, 2=Add. heat only |
| 48043 | String | 0 | 10 | Setting | Holiday - Activated | 0=inactive, 10=active |
| 48046 | Number | -10 | 10 | Setting | Heat Offset Holiday | |
| 48047 | String | -1 | 2 | Setting | Hot water mode Holiday | -1 = off, 0 = economy, 1 = normal, 2 = luxury |
| 48053 | Number | 0 | 100 | Setting | FLM 2 speed 4 | |
| 48054 | Number | 0 | 100 | Setting | FLM 2 speed 3 | |
| 48055 | Number | 0 | 100 | Setting | FLM 2 speed 2 | |
Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -660,6 +660,10 @@ public class F1X45 {
put(47370, new VariableInformation( 1, NibeDataType.U8 , Type.SETTING , "Allow Additive Heating"));
put(47371, new VariableInformation( 1, NibeDataType.U8 , Type.SETTING , "Allow Heating"));
put(47372, new VariableInformation( 1, NibeDataType.U8 , Type.SETTING , "Allow Cooling"));
put(47374, new VariableInformation( 10, NibeDataType.S16, Type.SETTING , "Start Temperature Cooling"));
put(47375, new VariableInformation( 10, NibeDataType.S16, Type.SETTING , "Stop Temperature Heating"));
put(47376, new VariableInformation( 10, NibeDataType.S16, Type.SETTING , "Stop Temperature Additive"));
put(47377, new VariableInformation( 1, NibeDataType.U8 , Type.SETTING , "Outdoor Filter Time"));
put(47378, new VariableInformation( 10, NibeDataType.S16, Type.SETTING , "Max diff. comp."));
put(47379, new VariableInformation( 10, NibeDataType.S16, Type.SETTING , "Max diff. add."));
put(47380, new VariableInformation( 1, NibeDataType.U8 , Type.SETTING , "Low brine out autoreset"));
Expand Down Expand Up @@ -695,6 +699,9 @@ public class F1X45 {
put(47540, new VariableInformation( 1, NibeDataType.S16, Type.SETTING , "Heat DM diff"));
put(47543, new VariableInformation( 1, NibeDataType.S16, Type.SETTING , "Cooling DM diff"));
put(47570, new VariableInformation( 1, NibeDataType.U8 , Type.SETTING , "Operational mode"));
put(48043, new VariableInformation( 1, NibeDataType.U8 , Type.SETTING , "Holiday - Activated"));
put(48046, new VariableInformation( 1, NibeDataType.S8 , Type.SETTING , "Heat Offset Holiday"));
put(48047, new VariableInformation( 1, NibeDataType.S8 , Type.SETTING , "Hot water mode Holiday"));
put(48053, new VariableInformation( 1, NibeDataType.U8 , Type.SETTING , "FLM 2 speed 4"));
put(48054, new VariableInformation( 1, NibeDataType.U8 , Type.SETTING , "FLM 2 speed 3"));
put(48055, new VariableInformation( 1, NibeDataType.U8 , Type.SETTING , "FLM 2 speed 2"));
Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -641,6 +641,10 @@
<channel id="47370" typeId="f1x45-47370"/>
<channel id="47371" typeId="f1x45-47371"/>
<channel id="47372" typeId="f1x45-47372"/>
<channel id="47374" typeId="f1x45-47374"/>
<channel id="47375" typeId="f1x45-47375"/>
<channel id="47376" typeId="f1x45-47376"/>
<channel id="47377" typeId="f1x45-47377"/>
<channel id="47378" typeId="f1x45-47378"/>
<channel id="47379" typeId="f1x45-47379"/>
<channel id="47380" typeId="f1x45-47380"/>
Expand Down Expand Up @@ -676,6 +680,9 @@
<channel id="47540" typeId="f1x45-47540"/>
<channel id="47543" typeId="f1x45-47543"/>
<channel id="47570" typeId="f1x45-47570"/>
<channel id="48043" typeId="f1x45-48043"/>
<channel id="48046" typeId="f1x45-48046"/>
<channel id="48047" typeId="f1x45-48047"/>
<channel id="48053" typeId="f1x45-48053"/>
<channel id="48054" typeId="f1x45-48054"/>
<channel id="48055" typeId="f1x45-48055"/>
Expand Down
Original file line number Diff line number Diff line change
Expand Up @@ -4600,6 +4600,34 @@
<description>Whether to allow cooling (only valid for operational mode Manual or Add. heat only)</description>
<state readOnly="false"></state>
</channel-type>
<channel-type id="f1x45-47374" advanced="true">
<item-type>Number</item-type>
<label>Start Temperature Cooling</label>
<description>Start temperature for cooling</description>
<state min="-200" max="400" step="1" pattern="%.1f °C" readOnly="false">
</state>
</channel-type>
<channel-type id="f1x45-47375" advanced="true">
<item-type>Number</item-type>
<label>Stop Temperature Heating</label>
<description>Stop temperature for heating</description>
<state min="-200" max="400" step="1" pattern="%.1f °C" readOnly="false">
</state>
</channel-type>
<channel-type id="f1x45-47376" advanced="true">
<item-type>Number</item-type>
<label>Stop Temperature Additive</label>
<description>Stop temperature for additive</description>
<state min="-250" max="400" step="1" pattern="%.1f °C" readOnly="false">
</state>
</channel-type>
<channel-type id="f1x45-47377" advanced="true">
<item-type>Number</item-type>
<label>Outdoor Filter Time</label>
<description>Filter time in hours</description>
<state min="0" max="48" step="1" pattern="%d h" readOnly="false">
</state>
</channel-type>
<channel-type id="f1x45-47378" advanced="true">
<item-type>Number</item-type>
<label>Max Diff. Comp.</label>
Expand Down Expand Up @@ -4854,6 +4882,38 @@
</options>
</state>
</channel-type>
<channel-type id="f1x45-48043" advanced="true">
<item-type>String</item-type>
<label>Holiday - Activated</label>
<description>0=inactive, 10=active</description>
<state min="0" max="10" step="1" pattern="%d" readOnly="false">
<options>
<option value="0">inactive</option>
<option value="10">active</option>
</options>
</state>
</channel-type>
<channel-type id="f1x45-48046" advanced="true">
<item-type>Number</item-type>
<label>Heat Offset Holiday</label>
<description>Offset of the heat curve, Holiday</description>
<state min="-10" max="10" step="1" pattern="%d" readOnly="false">
</state>
</channel-type>
<channel-type id="f1x45-48047" advanced="true">
<item-type>String</item-type>
<label>Hot water mode Holiday</label>
<description>Hot water comfort mode Holiday, -1 = off, 0 = economy, 1 = normal, 2 = luxury
</description>
<state min="-1" max="2" step="1" pattern="%d" readOnly="false">
<options>
<option value="-1">off</option>
<option value="0">economy</option>
<option value="1">normal</option>
<option value="2">luxury</option>
</options>
</state>
</channel-type>
<channel-type id="f1x45-48053" advanced="true">
<item-type>Number</item-type>
<label>FLM 2 Speed 4</label>
Expand Down