25 changes: 17 additions & 8 deletions canopen/profiles/p402.py
Original file line number Diff line number Diff line change
Expand Up @@ -212,22 +212,31 @@ def __init__(self, node_id, object_dictionary):
self.tpdo_pointers = {} # { index: pdo.Map instance }
self.rpdo_pointers = {} # { index: pdo.Map instance }

def setup_402_state_machine(self):
def setup_402_state_machine(self, read_pdos=True):
"""Configure the state machine by searching for a TPDO that has the StatusWord mapped.

:param bool read_pdos: Upload current PDO configuration from node.
:raises ValueError:
If the the node can't find a Statusword configured in any of the TPDOs.
"""
self.nmt.state = 'PRE-OPERATIONAL' # Why is this necessary?
self.setup_pdos()
self.setup_pdos(read_pdos)
self._check_controlword_configured()
self._check_statusword_configured()
self._check_op_mode_configured()
self.nmt.state = 'OPERATIONAL'
self.state = 'SWITCH ON DISABLED' # Why change state?

def setup_pdos(self):
self.pdo.read() # TPDO and RPDO configurations
def setup_pdos(self, upload=True):
"""Find the relevant PDO configuration to handle the state machine.

:param bool upload:
Retrieve up-to-date configuration via SDO. If False, the node's mappings must
already be configured in the object, matching the drive's settings.
:raises AssertionError:
When the node's NMT state disallows SDOs for reading the PDO configuration.
"""
if upload:
assert self.nmt.state in 'PRE-OPERATIONAL', 'OPERATIONAL'
self.pdo.read() # TPDO and RPDO configurations
else:
self.pdo.subscribe() # Get notified on reception, usually a side-effect of read()
self._init_tpdo_values()
self._init_rpdo_pointers()

Expand Down
30 changes: 16 additions & 14 deletions doc/profiles.rst
Original file line number Diff line number Diff line change
Expand Up @@ -34,10 +34,13 @@ The current status can be read from the device by reading the register
0x6041, which is called the "Statusword".
Changes in state can only be done in the 'OPERATIONAL' state of the NmtMaster

TPDO1 needs to be set up correctly. For this, run the the
`BaseNode402.setup_402_state_machine()` method. Note that this setup
routine will change only TPDO1 and automatically go to the 'OPERATIONAL' state
of the NmtMaster::
PDOs with the Controlword and Statusword mapped need to be set up correctly,
which is the default configuration of most DS402-compatible drives. To make
them accessible to the state machine implementation, run the the
`BaseNode402.setup_402_state_machine()` method. Note that this setup routine
will read the current PDO configuration by default, causing some SDO traffic.
That works only in the 'OPERATIONAL' or 'PRE-OPERATIONAL' states of the
:class:`NmtMaster`::

# run the setup routine for TPDO1 and it's callback
some_node.setup_402_state_machine()
Expand All @@ -50,21 +53,20 @@ Write Controlword and read Statusword::
# Read the state of the Statusword
some_node.sdo[0x6041].raw

During operation the state can change to states which cannot be commanded
by the Controlword, for example a 'FAULT' state.
Therefore the :class:`PowerStateMachine` class (in similarity to the :class:`NmtMaster`
class) automatically monitors state changes of the Statusword which is sent
by TPDO1. The available callback on thet TPDO1 will then extract the
information and mirror the state change in the :attr:`BaseNode402.powerstate_402`
attribute.
During operation the state can change to states which cannot be commanded by the
Controlword, for example a 'FAULT' state. Therefore the :class:`BaseNode402`
class (in similarity to :class:`NmtMaster`) automatically monitors state changes
of the Statusword which is sent by TPDO. The available callback on that TPDO
will then extract the information and mirror the state change in the
:attr:`BaseNode402.state` attribute.

Similar to the :class:`NmtMaster` class, the states of the :class:`BaseNode402`
class :attr:`._state` attribute can be read and set (command) by a string::
class :attr:`.state` attribute can be read and set (command) by a string::

# command a state (an SDO message will be called)
some_node.powerstate_402.state = 'SWITCHED ON'
some_node.state = 'SWITCHED ON'
# read the current state
some_node.powerstate_402.state = 'SWITCHED ON'
some_node.state = 'SWITCHED ON'

Available states:

Expand Down