Let meca use -C for cpt like the rest of GMT #4873
Merged
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
See #4869 for context. In the refreshing process for common CPT settings we also needed to move -C to -A. This was all done with backwards compatibility in mind. Existing scripts run as before. Note: The circle drawn at the original epicenter (-C, now -A) was zero size in GMT 3-4 and became nonzero but not discernible in GMT 5-6.1.1 (size 0.005 inches). We now simply state the circle is optional and users can set a nonzero diameter if they want it rather than get a speck of dirt on their plot. This PR completes the prepping discussed in #4869 and complements #4870.