Fix DS402 documentation to match the implementation.
Browse files Browse the repository at this point in the history
Besides the changes regarding setup_402_state_machine(), there were
numerous errors where the documentation talks about nonexistent or
differently named attributes.

Also fix the description regaring what the method actually does.  It
won't configure the TPDO1 to contain the Statusword, but only check
the PDO configuration for Statusword and Controlword presence.
  • Loading branch information
acolomb committed Aug 12, 2021
1 parent 10da15a commit 3b51936
Showing 1 changed file with 16 additions and 14 deletions.
30 changes: 16 additions & 14 deletions doc/profiles.rst
Original file line number Diff line number Diff line change
Expand Up @@ -34,10 +34,13 @@ The current status can be read from the device by reading the register
0x6041, which is called the "Statusword".
Changes in state can only be done in the 'OPERATIONAL' state of the NmtMaster

TPDO1 needs to be set up correctly. For this, run the the
`BaseNode402.setup_402_state_machine()` method. Note that this setup
routine will change only TPDO1 and automatically go to the 'OPERATIONAL' state
of the NmtMaster::
PDOs with the Controlword and Statusword mapped need to be set up correctly,
which is the default configuration of most DS402-compatible drives. To make
them accessible to the state machine implementation, run the the
`BaseNode402.setup_402_state_machine()` method. Note that this setup routine
will read the current PDO configuration by default, causing some SDO traffic.
That works only in the 'OPERATIONAL' or 'PRE-OPERATIONAL' states of the
:class:`NmtMaster`::

# run the setup routine for TPDO1 and it's callback
some_node.setup_402_state_machine()
Expand All @@ -50,21 +53,20 @@ Write Controlword and read Statusword::
# Read the state of the Statusword
some_node.sdo[0x6041].raw

During operation the state can change to states which cannot be commanded
by the Controlword, for example a 'FAULT' state.
Therefore the :class:`PowerStateMachine` class (in similarity to the :class:`NmtMaster`
class) automatically monitors state changes of the Statusword which is sent
by TPDO1. The available callback on thet TPDO1 will then extract the
information and mirror the state change in the :attr:`BaseNode402.powerstate_402`
attribute.
During operation the state can change to states which cannot be commanded by the
Controlword, for example a 'FAULT' state. Therefore the :class:`BaseNode402`
class (in similarity to :class:`NmtMaster`) automatically monitors state changes
of the Statusword which is sent by TPDO. The available callback on that TPDO
will then extract the information and mirror the state change in the
:attr:`BaseNode402.state` attribute.

Similar to the :class:`NmtMaster` class, the states of the :class:`BaseNode402`
class :attr:`._state` attribute can be read and set (command) by a string::
class :attr:`.state` attribute can be read and set (command) by a string::

# command a state (an SDO message will be called)
some_node.powerstate_402.state = 'SWITCHED ON'
some_node.state = 'SWITCHED ON'
# read the current state
some_node.powerstate_402.state = 'SWITCHED ON'
some_node.state = 'SWITCHED ON'

Available states: