Fix: convert salinity and relativeHumidity in VDM from percentage values to ratio #254
+7
−4
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
Issue: (#253)
salinity
andrelativeHumidity
paths in the specification (environment
group) are defined with the unitratio
.Values from the VDM sentence are written to these signal K paths as a number representing a percentage (e.g. 80) rather than a ratio (i.e. 0.8).