Releases: Gissio/radpro
2.1
By downloading this software, you agree to the Rad Pro terms and conditions.
Note: this release requires an installation.
Release updates:
- Added the ability to dismiss alarms with the reset measurement key.
- Added configurable alarm signaling: sound, vibration, pulse LED and display flash.
- Added an alarm enabled indicator.
- Implemented a keyboard lock mode, accessible from Settings.
- Display of dose counts below 10000 now shown in standard notation.
- Added new rate and dose alarm options.
- Added new average timer options.
- Extended the dead-time compensation range to 20-320 µs.
- Added the ability to toggle pulse sounds from the measurement view on supported devices.
- Added a new pulses chirps sound option.
- Extended the duration of alarm sounds.
- Enhanced the menu structure for more intuitive navigation.
- Updated the UI font to Open Sans for enhanced readability.
- Minor UI improvements.
Release fixes:
- On color displays, fixed an issue causing an unsightly flash when waking from sleep mode.
- Fixed alarms continuing to sound after device shutdown while connected to external power.
- Corrected the display of secondary rate and count views after the average timer expired.
- Resolved an issue where the device state wasn't reset after a quick power cycle.
- Corrected a problem where 1 minute instantaneous averaging at high radiation levels didn't average correctly.
2.0.3 "The sensitive update"
By downloading this software, you agree to the Rad Pro terms and conditions.
Note: this release requires an installation.
Release notes:
- Extended conversion factor range to 25-12800 cpm/µSv/h.
- When using sensitive detectors with a conversion factor of 600 cpm/µSv/h or higher, pulse indication is now capped at 600 cpm/µSv/h to provide approximately one pulse per second at background levels of radiation. This does not impact the actual measurements.
- Minor UI and performance refinements.
- Added the Rad Pro simulator.
2.0.2 "The precise release" (flashtool v2)
By downloading this software, you agree to the Rad Pro terms and conditions.
Instructions:
- Use the update version if you have Rad Pro 2.0.1 installed.
- Use the install version if you have Rad Pro 2.0.0 or earlier intalled.
Release notes:
- Improved the instantaneous rate averaging algorithm.
- Simplified the instantaneous rate averaging response curves, resulting in improved precision when using J613/J614 tubes.
- Disabled instantaneous rate alarms in situations where the confidence interval is high, such as immediately after device startup.
- Minor UI improvements.
- Fixes an error in the flashtool (with FNIRSI GC-01 devices).
2.0.1 "Nobody's perfect"
By downloading this software, you agree to the Rad Pro terms and conditions.
Notes:
- Added data log reset.
- Changed the default conversion factor for J613/J614 tubes to 60.0 cpm/µSv/h.
- Resolved issues with custom HV profiles.
- Resolved issues with the "SET tubeHVFrequency" and "SET tubeHVDutyCycle" data connection requests.
- Resolved issues with new history data log download.
- Minor refinements.
2.0 "Grand première"
By downloading this software, you agree to the Rad Pro terms and conditions.
Notes:
- First 2.0 release.
- Updated the UI design system to OpenBridge 5.0, improving legibility under sunlight.
- Changed the default conversion factor for J613/J614 tubes to 30.0 cpm/µSv/h.
- Removed the FNIRSI GC-01 display panel settings.
- Increased the granularity and range of the "SET tubeHVFrequency" and "SET tubeHVDutyCycle" data connection requests to 100 Hz-100 kHz and 0 %-100 %, respectively (not stored on power-off).
2.0rc5 "The final countdown"
By downloading this software, you agree to the Rad Pro terms and conditions.
On FNIRSI GC-01 devices, make sure you select the correct display panel in display settings!
Notes:
- Added Bosean FS-5000 support.
- Added display panel menu for selecting the display panel (on supported devices).
- Added secondary dose view in average measurement mode.
- Extended conversion factor range to 25-1600 cpm/µSv/h.
- Added 1 second datalog interval options and removed 30 seconds and 30 minutes datalog interval options.
- Added "SET tubeHVFrequency" and "SET tubeHVDutyCycle" data connection commands.
- Added 12-hour time format.
- Devices with data mode allow using the device while data mode is active; data mode state is also preserved after powering off.
- Improved battery level indicator of the Bosean FS-600/FS-1000.
- Improved battery level readout of the FS2011(STM32F051), Bosean FS-600/FS-1000.
- Improved keyboard control scheme of the Bosean FS-1000.
- Changed USB data connection end of line to "\r\n".
- Minor refinements.
2.0rc4 "The little update"
By downloading this software, you agree to the Rad Pro terms and conditions.
Notes:
- Added instantaneous rate averaging options: adaptive fast, adaptive precision, 60 seconds, 30 seconds and 10 seconds.
- Added secondary CPM and count displays in measurement views.
- Improved haptic pulse strengths.
- Improved FNIRSI GC-01 quiet pulse clicks.
- Improved selected menu item contrast.
- Improved datalogging time precision.
- Fixed History (24 h) bug.
2.0rc3 "The BIG update"
By downloading this software, you agree to the Rad Pro terms and conditions.
Notes:
- UI update with BIG numbers.
- Instantaneous rate bar with alert zones (1 µSv, 10 µSv).
- History alert zones (1 µSv, 10 µSv).
- Average timer expiration after reaching a configurable confidence interval.
- Background compensation.
- Display flashes on the FNIRSI GC-01 (after display sleep).
- Haptic pulses on the FNIRSI GC-01 (off, weak or strong).
- Pulses threshold (disables pulse indication if instantaneous rate is below a certain value).
- Fault alarm on HV/tube failure (lack of pulses) or tube saturation (tube shorted).
- Added 30 second and 10 second datalog interval options.
- Added 10 second display sleep option.
- Added
radpro-flashtool
. - Removed hold option.
2.0rc2
By downloading this software, you agree to the Rad Pro terms and conditions.
Notes:
- Changed default display theme to Dusk.
- Fixed flash programming code.
- Fixed FNIRSI GC-01 battery indicator.
- Fixed conversion factor menu logic.
1.3.0
By downloading this software, you agree to the Rad Pro terms and conditions.
Note: Rad Pro 1.3.0 uses a new settings format, thus requiring an installation rather than an update.
Notes:
- Added data logging.
- Added custom conversion factors.
- Added support for the J305 Geiger tube.
- Minor bug fixes.