Skip to content

Commit

Permalink
Ensure pythoncom is uninitialised properly after use
Browse files Browse the repository at this point in the history
  • Loading branch information
Crozzers committed Nov 17, 2024
1 parent a9b1084 commit 680c47b
Showing 1 changed file with 117 additions and 107 deletions.
224 changes: 117 additions & 107 deletions screen_brightness_control/windows.py
Original file line number Diff line number Diff line change
@@ -1,6 +1,8 @@
import logging
import re
import threading
import time
from contextlib import contextmanager
from ctypes import Structure, WinError, byref, windll
from ctypes.wintypes import BYTE, DWORD, HANDLE, WCHAR
from typing import List, Optional
Expand All @@ -10,7 +12,7 @@
import win32api
import win32con
import wmi
import re

from . import filter_monitors, get_methods
from .exceptions import EDIDParseError, NoValidDisplayError, format_exc
from .helpers import EDID, BrightnessMethod, __Cache, _monitor_brand_lookup
Expand All @@ -34,15 +36,21 @@
'''


@contextmanager
def _wmi_init():
'''internal function to create and return a wmi instance'''
# WMI calls don't work in new threads so we have to run this check
if threading.current_thread() != threading.main_thread():
com_init = threading.current_thread() != threading.main_thread()
if com_init:
if COM_MODEL is None:
pythoncom.CoInitialize()
else:
pythoncom.CoInitializeEx(COM_MODEL)
return wmi.WMI(namespace='wmi')

yield wmi.WMI(namespace='wmi')

if com_init:
pythoncom.CoUninitialize()


def enum_display_devices() -> Generator[win32api.PyDISPLAY_DEVICEType, None, None]:
Expand Down Expand Up @@ -87,92 +95,92 @@ def get_display_info() -> List[dict]:
monitor_uids[device.DeviceID.split('#')[2]] = device

# gather list of laptop displays to check against later
wmi = _wmi_init()
try:
laptop_displays = [
i.InstanceName
for i in wmi.WmiMonitorBrightness()
]
except Exception as e:
# don't do specific exception classes here because WMI does not play ball with it
_logger.warning(
f'get_display_info: failed to gather list of laptop displays - {format_exc(e)}')
laptop_displays = []

extras, desktop, laptop = [], 0, 0
uid_keys = list(monitor_uids.keys())
for monitor in wmi.WmiMonitorDescriptorMethods():
model, serial, manufacturer, man_id, edid = None, None, None, None, None
instance_name = monitor.InstanceName.replace(
'_0', '', 1).split('\\')[2]
try:
pydevice = monitor_uids[instance_name]
except KeyError:
# if laptop display WAS connected but was later put to sleep (#33)
if instance_name in laptop_displays:
laptop += 1
else:
desktop += 1
_logger.warning(
f'display {instance_name!r} is detected but not present in monitor_uids.'
' Maybe it is asleep?'
)
continue

# get the EDID
with _wmi_init() as wmi:
try:
edid = ''.join(
f'{char:02x}' for char in monitor.WmiGetMonitorRawEEdidV1Block(0)[0])
# we do the EDID parsing ourselves because calling wmi.WmiMonitorID
# takes too long
parsed = EDID.parse(edid)
man_id, manufacturer, model, name, serial = parsed
if name is None:
raise EDIDParseError(
'parsed EDID returned invalid display name')
except EDIDParseError as e:
edid = None
_logger.warning(
f'exception parsing edid str for {monitor.InstanceName} - {format_exc(e)}')
laptop_displays = [
i.InstanceName
for i in wmi.WmiMonitorBrightness()
]
except Exception as e:
edid = None
_logger.error(
f'failed to get EDID string for {monitor.InstanceName} - {format_exc(e)}')
finally:
if edid is None:
devid = pydevice.DeviceID.split('#')
serial = devid[2]
man_id = devid[1][:3]
model = devid[1][3:] or 'Generic Monitor'
del devid
if (brand := _monitor_brand_lookup(man_id)):
man_id, manufacturer = brand

if (serial, model) != (None, None):
data: dict = {
'name': f'{manufacturer} {model}',
'model': model,
'serial': serial,
'manufacturer': manufacturer,
'manufacturer_id': man_id,
'edid': edid,
'uid': uid_match.group(1) if (uid_match := re.search(r"UID(\d+)", instance_name)) else None,
}
if monitor.InstanceName in laptop_displays:
data['index'] = laptop
data['method'] = WMI
laptop += 1
else:
data['method'] = VCP
desktop += 1

if instance_name in uid_keys:
# insert the data into the uid_keys list because
# uid_keys has the monitors sorted correctly. This
# means we don't have to re-sort the list later
uid_keys[uid_keys.index(instance_name)] = data
else:
extras.append(data)
# don't do specific exception classes here because WMI does not play ball with it
_logger.warning(
f'get_display_info: failed to gather list of laptop displays - {format_exc(e)}')
laptop_displays = []

extras, desktop, laptop = [], 0, 0
uid_keys = list(monitor_uids.keys())
for monitor in wmi.WmiMonitorDescriptorMethods():
model, serial, manufacturer, man_id, edid = None, None, None, None, None
instance_name = monitor.InstanceName.replace(
'_0', '', 1).split('\\')[2]
try:
pydevice = monitor_uids[instance_name]
except KeyError:
# if laptop display WAS connected but was later put to sleep (#33)
if instance_name in laptop_displays:
laptop += 1
else:
desktop += 1
_logger.warning(
f'display {instance_name!r} is detected but not present in monitor_uids.'
' Maybe it is asleep?'
)
continue

# get the EDID
try:
edid = ''.join(
f'{char:02x}' for char in monitor.WmiGetMonitorRawEEdidV1Block(0)[0])
# we do the EDID parsing ourselves because calling wmi.WmiMonitorID
# takes too long
parsed = EDID.parse(edid)
man_id, manufacturer, model, name, serial = parsed
if name is None:
raise EDIDParseError(
'parsed EDID returned invalid display name')
except EDIDParseError as e:
edid = None
_logger.warning(
f'exception parsing edid str for {monitor.InstanceName} - {format_exc(e)}')
except Exception as e:
edid = None
_logger.error(
f'failed to get EDID string for {monitor.InstanceName} - {format_exc(e)}')
finally:
if edid is None:
devid = pydevice.DeviceID.split('#')
serial = devid[2]
man_id = devid[1][:3]
model = devid[1][3:] or 'Generic Monitor'
del devid
if (brand := _monitor_brand_lookup(man_id)):
man_id, manufacturer = brand

if (serial, model) != (None, None):
data: dict = {
'name': f'{manufacturer} {model}',
'model': model,
'serial': serial,
'manufacturer': manufacturer,
'manufacturer_id': man_id,
'edid': edid,
'uid': uid_match.group(1) if (uid_match := re.search(r"UID(\d+)", instance_name)) else None,
}
if monitor.InstanceName in laptop_displays:
data['index'] = laptop
data['method'] = WMI
laptop += 1
else:
data['method'] = VCP
desktop += 1

if instance_name in uid_keys:
# insert the data into the uid_keys list because
# uid_keys has the monitors sorted correctly. This
# means we don't have to re-sort the list later
uid_keys[uid_keys.index(instance_name)] = data
else:
extras.append(data)

info = uid_keys + extras
if desktop:
Expand Down Expand Up @@ -205,21 +213,23 @@ def get_display_info(cls, display: Optional[DisplayIdentifier] = None) -> List[d

@classmethod
def set_brightness(cls, value: IntPercentage, display: Optional[int] = None):
brightness_method = _wmi_init().WmiMonitorBrightnessMethods()
if display is not None:
brightness_method = [brightness_method[display]]
with _wmi_init() as wmi:
brightness_method = wmi.WmiMonitorBrightnessMethods()
if display is not None:
brightness_method = [brightness_method[display]]

for method in brightness_method:
method.WmiSetBrightness(value, 0)
for method in brightness_method:
method.WmiSetBrightness(value, 0)

@classmethod
def get_brightness(cls, display: Optional[int] = None) -> List[IntPercentage]:
brightness_method = _wmi_init().WmiMonitorBrightness()
if display is not None:
brightness_method = [brightness_method[display]]
with _wmi_init() as wmi:
brightness_method = wmi.WmiMonitorBrightness()
if display is not None:
brightness_method = [brightness_method[display]]

values = [i.CurrentBrightness for i in brightness_method]
return values
values = [i.CurrentBrightness for i in brightness_method]
return values


class VCP(BrightnessMethod):
Expand Down Expand Up @@ -250,16 +260,16 @@ def iter_physical_monitors(cls, start: int = 0) -> Generator[HANDLE, None, None]
monitor_index = 0
display_devices = list(enum_display_devices())

wmi = _wmi_init()
try:
laptop_displays = [
i.InstanceName.replace('_0', '').split('\\')[2]
for i in wmi.WmiMonitorBrightness()
]
except Exception as e:
cls._logger.warning(
f'failed to gather list of laptop displays - {format_exc(e)}')
laptop_displays = []
with _wmi_init() as wmi:
try:
laptop_displays = [
i.InstanceName.replace('_0', '').split('\\')[2]
for i in wmi.WmiMonitorBrightness()
]
except Exception as e:
cls._logger.warning(
f'failed to gather list of laptop displays - {format_exc(e)}')
laptop_displays = []

for monitor in map(lambda m: m[0].handle, win32api.EnumDisplayMonitors()):
# Get physical monitor count
Expand Down

0 comments on commit 680c47b