[0.1-t03_11] sensor hub goes offline #11

Open
cntlsn opened this issue Feb 7, 2017 · 0 comments
Open

[0.1-t03_11] sensor hub goes offline #11

cntlsn opened this issue Feb 7, 2017 · 0 comments

Comments

@cntlsn
Copy link
Member

cntlsn commented Feb 7, 2017

when removing/commenting the display on LCD of the Accelerometer Inactivity delta on line 403 of https://github.com/opencarecc/inpe/blob/0.1-t03_10/software/inpe-t03_010/inpe-t03_010.ino, the sensor hub tends go offline every once in a while for a some milliseconds

@cntlsn cntlsn added the BUG label Feb 7, 2017