Notifications
You must be signed in to change notification settings - Fork 0
/
Copy pathapp.yaml
313 lines (270 loc) · 13.5 KB
/
app.yaml
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
# ------------------------------------------------------------------
# This is an example configuration, please modify it
# ------------------------------------------------------------------
---
pred_bat:
module: predbat
class: PredBat
# Sets the prefix for all created entities in HA - only change if you want to run more than once instance
prefix: predbat
# Timezone to work in
timezone: Europe/London
# Currency, symbol for main currency second symbol for 1/100s e.g. $ c or £ p or e c
currency_symbols:
- '£'
- 'p'
# Number of threads to use in plan calculation
# Can be auto for automatic, 0 for off or values 1-N for a fixed number
threads: auto
# inverter_type: "LXP"
num_inverters: 1
# XXX: This is a configuration template, delete this line once you edit your configuration
template: True
#
# Sensors, more than one can be specified and they will be summed up automatically
#
# For two inverters the load today would normally be the master load sensor only (to cover the entire house)
# If you have three phase and one inverter per phase then you would need three load sensors
#
# For pv_today if you have multiple solar inverter inputs then you should include one entry for each inverter
#
import_today:
- sensor.lxp_XXXXXXX_energy_from_grid_today
export_today:
- sensor.lxp_XXXXXXX_energy_to_grid_today
pv_today:
- sensor.lxp_XXXXXXX_pv_generation_today
load_today:
- sensor.lxp_calculated_consumption
# Controls/status - must by 1 per inverter
#
num_inverters: 1
# Services to control charging/discharging
charge_start_service:
service: switch.turn_on
entity_id: "switch.lxp_XXXXXX_ac_charge"
charge_stop_service:
service: switch.turn_off
entity_id: "switch.lxp_XXXXXX_ac_charge"
#
# Run balance inverters every N seconds (0=disabled) - only for multi-inverter
#balance_inverters_seconds: 60
#
# If not using REST then instead set the Control here (one for each inverter)
# You should keep this section even when using REST as a fallback if it fails and for charge curve calculations
# charge_rate:
# - number.givtcp_{geserial}_battery_charge_rate
# Max inverter power from battery
battery_rate_max:
- 4000
soc_percent:
- sensor.lxp_XXXXXX_state_of_charge
# battery_power:
# - sensor.givtcp_{geserial}_battery_power
# - sensor.givtcp2_{geserial2}_battery_power
pv_power:
- sensor.lxp_XXXXXX_pv_power_array
# Battery capacity in kWh
soc_max:
- 9.3
reserve:
- 10
charge_start_time:
- 00:00:00
charge_end_time:
- 01:00:00
charge_limit:
- 100
scheduled_charge_enable:
- off
scheduled_discharge_enable:
- off
discharge_start_time:
- 00:00:00
discharge_end_time:
- 00:00:00
# Inverter max AC limit (one per inverter). E.g for a 3.6kw inverter set to 3600
# If you have a second inverter for PV only please add the two values together
inverter_limit:
- 6000
# Export limit is a software limit set on your inverter that prevents exporting above a given level
# When enabled Predbat will model this limit
#export_limit:
# - 3600
# - 3600
# Some inverters don't turn off when the rate is set to 0, still charge or discharge at around 200w
# The value can be set here in watts to model this (doesn't change operation)
#inverter_battery_rate_min:
# - 200
# Workaround to limit the maximum reserve setting, some inverters won't allow 100% to be set
# Comment out if your inverter allows 100%
#inverter_reserve_max : 98
# Some batteries tail off their charge rate at high soc%
# enter the charging curve here as a % of the max charge rate for each soc percentage.
# the default is 1.0 (full power)
# The example below is from GE 9.5kwh battery with latest firmware and gen1 inverter
#
# Predbat can compute this curve automatically if you have enough data, restart the add-on and look in the logfile for the data
# once set here Predbat will no longer re-compute the curve.
# Can also be set to 'auto' to just use the calculation curve, not recommended if you are using low power charging mode.
#battery_charge_power_curve:
# 91 : 0.91
# 92 : 0.81
# 93 : 0.71
# 94 : 0.62
# 95 : 0.52
# 96 : 0.43
# 97 : 0.33
# 98 : 0.24
# 99 : 0.24
# 100 : 0.24
#battery_discharge_power_curve:
# 4 : 1.0
# Inverter clock skew in minutes, e.g. 1 means it's 1 minute fast and -1 is 1 minute slow
# Separate start and end options are applied to the start and end time windows, mostly as you want to start late (not early) and finish early (not late)
# Separate discharge skew for discharge windows only
inverter_clock_skew_start: 0
inverter_clock_skew_end: 0
inverter_clock_skew_discharge_start: 0
inverter_clock_skew_discharge_end: 0
# Clock skew adjusts the Appdaemon time
# This is the time that Predbat takes actions like starting discharge/charging
# Only use this for workarounds if your inverter time is correct but Predbat is somehow wrong (AppDaemon issue)
# 1 means add 1 minute to AppDaemon time, -1 takes it away
clock_skew: 0
# Set these to match solcast sensor names
# The regular expression (re:) makes the solcast bit optional
# If these don't match find your own names in Home Assistant
pv_forecast_today: re:(sensor.(solcast_|)(pv_forecast_|)forecast_today)
pv_forecast_tomorrow: re:(sensor.(solcast_|)(pv_forecast_|)forecast_tomorrow)
pv_forecast_d3: re:(sensor.(solcast_|)(pv_forecast_|)forecast_(day_3|d3))
pv_forecast_d4: re:(sensor.(solcast_|)(pv_forecast_|)forecast_(day_4|d4))
# If you have Octopus intelligent, enable the intelligent slot information to add to pricing
# Will automatically disable if not found, or comment out to disable fully
# When enabled it overrides the 'car_charging_planned' feature and predict the car charging based on the intelligent plan (unless octopus intelligent charging is False)
# This matches either the intelligent slot from the Octopus Plugin or from the Intelligent plugin
octopus_intelligent_slot: 're:(binary_sensor.octopus_energy([0-9a-z_]+|)_intelligent_dispatching)'
octopus_ready_time: 're:(time.octopus_energy([0-9a-z_]+|)_intelligent_ready_time)'
octopus_charge_limit: 're:(number.octopus_energy([0-9a-z_]+|)_intelligent_charge_limit)'
# Example alternative configuration for Ohme integration release >=v0.6.1
#octopus_intelligent_slot: 'binary_sensor.ohme_slot_active'
#octopus_ready_time: 'time.ohme_target_time'
#octopus_charge_limit: 'number.ohme_target_percent'
# Energy rates
# Please set one of these three, if multiple are set then Octopus is used first, second rates_import/rates_export and latest basic metric
# Set import and export entity to point to the Octopus Energy plugin import and export sensors
# automatically matches your meter number assuming you have only one (no need to edit the below)
# Will be ignored if you don't have the sensor but will error if you do have one and it's incorrect
# NOTE: To get detailed energy rates you need to go in and manually enable the following events in HA
# event.octopus_energy_electricity_xxxxxxxx_previous_day_rates
# event.octopus_energy_electricity_xxxxxxxx_current_day_rates
# event.octopus_energy_electricity_xxxxxxxx_next_day_rates
# and if you have export enable:
# event.octopus_energy_electricity_xxxxxxxx_export_previous_day_rates
# event.octopus_energy_electricity_xxxxxxxx_export_current_day_rates
# event.octopus_energy_electricity_xxxxxxxx_export_next_day_rates
# Predbat will automatically find the event. entities from the link below to the sensors
metric_octopus_import: 're:(sensor.(octopus_energy_|)electricity_[0-9a-z]+_[0-9a-z]+_current_rate)'
metric_octopus_export: 're:(sensor.(octopus_energy_|)electricity_[0-9a-z]+_[0-9a-z]+_export_current_rate)'
# Standing charge in pounds, can be set to a sensor or manually entered (e.g. 0.50 is 50p)
# The default below will pick up the standing charge from the Octopus Plugin
# The standing charge only impacts the cost graphs and doesn't change the way Predbat plans
# If you don't want to show the standing charge then just delete this line or set to zero
metric_standing_charge: 're:(sensor.(octopus_energy_|)electricity_[0-9a-z]+_[0-9a-z]+_current_standing_charge)'
# Or set your actual rates across time for import and export
# If start/end is missing it's assumed to be a fixed rate
# Gaps are filled with zero rate
#rates_import:
# - start: "00:30:00"
# end: "04:30:00"
# rate: 7.5
# - start: "04:30:00"
# end: "00:30:00"
# rate: 40.0
#
#rates_export:
# - rate: 4.2
# Can be used instead of the plugin to get import rates directly online
# Overrides metric_octopus_import and rates_import
# rates_import_octopus_url : "https://api.octopus.energy/v1/products/FLUX-IMPORT-23-02-14/electricity-tariffs/E-1R-FLUX-IMPORT-23-02-14-A/standard-unit-rates"
# rates_import_octopus_url : "https://api.octopus.energy/v1/products/AGILE-FLEX-BB-23-02-08/electricity-tariffs/E-1R-AGILE-FLEX-BB-23-02-08-A/standard-unit-rates"
# Overrides metric_octopus_export and rates_export
# rates_export_octopus_url: "https://api.octopus.energy/v1/products/FLUX-EXPORT-BB-23-02-14/electricity-tariffs/E-1R-FLUX-EXPORT-BB-23-02-14-A/standard-unit-rates"
# rates_export_octopus_url: "https://api.octopus.energy/v1/products/AGILE-OUTGOING-BB-23-02-28/electricity-tariffs/E-1R-AGILE-OUTGOING-BB-23-02-28-A/standard-unit-rates/"
# rates_export_octopus_url: "https://api.octopus.energy/v1/products/OUTGOING-FIX-12M-BB-23-02-09/electricity-tariffs/E-1R-OUTGOING-FIX-12M-BB-23-02-09-A/standard-unit-rates/"
# Import rates can be overridden with rate_import_override
# Export rates can be overridden with rate_export_override
# Use the same format as above, but a date can be included if it just applies for a set day (e.g. Octopus power ups)
# This will override even the Octopus plugin rates if enabled
#
#rates_import_override:
# - date: '2023-09-10'
# start: '14:00:00'
# end: '14:30:00'
# rate: 112
# load_scaling: 0.8
# For pv estimate, leave blank for central estimate, or add 10 for 10% curve (worst case) or 90 or 90% curve (best case)
# If you use 10 then disable pv_metric10_weight below
# pv_estimate: 10
# Days previous is the number of days back to find historical load data
# Recommended is 7 to capture day of the week but 1 can also be used
# if you have more history you could use 7 and 14 (in a list) but the standard data in HA only lasts 10 days
days_previous:
- 7
# Days previous weight can be used to control the weighting of the previous load points, the values are multiplied by their
# weights and then divided through by the total weight. E.g. if you used 1 and 0.5 then the first value would have 2/3rd of the weight and the second 1/3rd
# Include one value for each days_previous value, each weighting on a separate line.
# If any days_previous's that are not given a weighting they will assume a default weighting of 1.
days_previous_weight:
- 1
# Number of hours forward to forecast, best left as-is unless you have specific reason
forecast_hours: 48
# Specify the devices that notifies are sent to, the default is 'notify' which goes to all
#notify_devices:
# - mobile_app_treforsiphone12_2
# Battery scaling makes the battery smaller (e.g. 0.9) or bigger than its reported
# If you have an 80% DoD battery that falsely reports it's kwh then set it to 0.8 to report the real figures
# One per inverter
battery_scaling:
- 1.0
# Can be used to scale import and export data, used for workarounds
import_export_scaling: 1.0
# Export triggers:
# For each trigger give a name, the minutes of export needed and the energy required in that time
# Multiple triggers can be set at once so in total you could use too much energy if all run
# Creates an entity called 'binary_sensor.predbat_export_trigger_<name>' which will be turned On when the condition is valid
# connect this to your automation to start whatever you want to trigger
export_triggers:
- name: 'large'
minutes: 60
energy: 1.0
- name: 'small'
minutes: 15
energy: 0.25
# If you have a sensor that gives the energy consumed by your solar diverter then add it here
# this will make the predictions more accurate. It should be an incrementing sensor, it can reset at midnight or not
# It's assumed to be in Kwh but scaling can be applied if need be
#iboost_energy_today: 'sensor.xxxxx'
#iboost_energy_scaling: 1.0
# Gas rates for comparison
#metric_octopus_gas: 're:(sensor.(octopus_energy_|)gas_[0-9a-z]+_[0-9a-z]+_current_rate)'
# Nordpool market energy rates
#futurerate_url: 'https://www.nordpoolgroup.com/api/marketdata/page/325?currency=GBP'
#futurerate_adjust_import: True
#futurerate_adjust_export: False
#futurerate_peak_start: "16:00:00"
#futurerate_peak_end: "19:00:00"
#futurerate_peak_premium_import: 14
#futurerate_peak_premium_export: 6.5
# Watch list, a list of sensors to watch for changes and then update the plan if they change
# This is useful for things like the Octopus Intelligent Slot sensor so that the plan update as soon as you plugin in
# Only uncomment the items you actually have set up above in apps.yaml, of course you can add your own as well
# Note those using +[] are lists that are appended to this list, whereas {} items are single items only
#watch_list:
# - '{octopus_intelligent_slot}'
# - '{octopus_ready_time}'
# - '{octopus_charge_limit}'
# - '{octopus_saving_session}'
# - '+[car_charging_planned]'
# - '+[car_charging_soc]'
# - '{car_charging_now}'