I had the same for SHT31 running on ESP32 - when i increased debug level to 3 it initialised properly ( not sure why, maybe due to debug it was just taking slightly more time to initialise and gave the heater the time to properly respond ? No idea) |
Same problem, but this repo fixed it! thank you! (had to double check the address to 0x44) |
Does any of garnes91, amizer12 or Emil want to send a PR ?
…On Tue, Sep 21, 2021 at 1:05 AM garnes91 ***@***.***> wrote:
Same problem, but this repo fixed it! thank you! (had to double check the
address to 0x44)
—
You are receiving this because you are subscribed to this thread.
Reply to this email directly, view it on GitHub
<#1 (comment)>,
or unsubscribe
<https://github.com/notifications/unsubscribe-auth/ACDRSPNN3BDPYXO6YSULCBLUC6447ANCNFSM4HW3T3JQ>
.
Triage notifications on the go with GitHub Mobile for iOS
<https://apps.apple.com/app/apple-store/id1477376905?ct=notification-email&mt=8&pt=524675>
or Android
<https://play.google.com/store/apps/details?id=com.github.android&referrer=utm_campaign%3Dnotification-email%26utm_medium%3Demail%26utm_source%3Dgithub>.
--
Pim van Pelt ***@***.***>
PBVP1-RIPE - http://www.ipng.nl/
|
Yes I will do that |
fix for issue mongoose-os-libs#1
For some reason this library does not work with every SHT30 sensor (3 sensors of 8 were working with this library) on a wemos D1 mini shield which can be found here:
Wemos D1 SHT30 shield
After forking this library and removing the status1 and status2 check (HEATER enable/DISABLE) the initialization succeeded and I could retrieve temperature and humidity from the sensor.
My changes can be found at: https://github.com/ebostijancic/sht30-i2c