title description ms.date
ADMX_WinInit Policy CSP
Learn more about the ADMX_WinInit Area in Policy CSP.
08/06/2024

Policy CSP - ADMX_WinInit

[!INCLUDE ADMX-backed CSP tip]

DisableNamedPipeShutdownPolicyDescription

Scope Editions Applicable OS
✅ Device
❌ User
✅ Pro
✅ Enterprise
✅ Education
✅ Windows SE
✅ IoT Enterprise / IoT Enterprise LTSC
✅ Windows 10, version 2004 with KB5005101 [10.0.19041.1202] and later
✅ Windows 10, version 20H2 with KB5005101 [10.0.19042.1202] and later
✅ Windows 10, version 21H1 with KB5005101 [10.0.19043.1202] and later
✅ Windows 11, version 21H2 [10.0.22000] and later
./Device/Vendor/MSFT/Policy/Config/ADMX_WinInit/DisableNamedPipeShutdownPolicyDescription

This policy setting controls the legacy remote shutdown interface (named pipe). The named pipe remote shutdown interface is needed in order to shutdown this system from a remote Windows XP or Windows Server 2003 system.

  • If you enable this policy setting, the system doesn't create the named pipe remote shutdown interface.

  • If you disable or don't configure this policy setting, the system creates the named pipe remote shutdown interface.

Description framework properties:

Property name Property value
Format chr (string)
Access Type Add, Delete, Get, Replace

[!INCLUDE ADMX-backed policy note]

ADMX mapping:

Name Value
Name DisableNamedPipeShutdownPolicyDescription
Friendly Name Turn off legacy remote shutdown interface
Location Computer Configuration
Path Windows Components > Shutdown Options
Registry Key Name Software\Microsoft\Windows\CurrentVersion\Policies\System
Registry Value Name DisableShutdownNamedPipe
ADMX File Name WinInit.admx

Hiberboot

Scope Editions Applicable OS
✅ Device
❌ User
✅ Pro
✅ Enterprise
✅ Education
✅ Windows SE
✅ IoT Enterprise / IoT Enterprise LTSC
✅ Windows 10, version 2004 with KB5005101 [10.0.19041.1202] and later
✅ Windows 10, version 20H2 with KB5005101 [10.0.19042.1202] and later
✅ Windows 10, version 21H1 with KB5005101 [10.0.19043.1202] and later
✅ Windows 11, version 21H2 [10.0.22000] and later
./Device/Vendor/MSFT/Policy/Config/ADMX_WinInit/Hiberboot

This policy setting controls the use of fast startup.

  • If you enable this policy setting, the system requires hibernate to be enabled.

  • If you disable or don't configure this policy setting, the local setting is used.

Description framework properties:

Property name Property value
Format chr (string)
Access Type Add, Delete, Get, Replace

[!INCLUDE ADMX-backed policy note]

ADMX mapping:

Name Value
Name Hiberboot
Friendly Name Require use of fast startup
Location Computer Configuration
Path System > Shutdown
Registry Key Name Software\Policies\Microsoft\Windows\System
Registry Value Name HiberbootEnabled
ADMX File Name WinInit.admx

ShutdownTimeoutHungSessionsDescription

Scope Editions Applicable OS
✅ Device
❌ User
✅ Pro
✅ Enterprise
✅ Education
✅ Windows SE
✅ IoT Enterprise / IoT Enterprise LTSC
✅ Windows 10, version 2004 with KB5005101 [10.0.19041.1202] and later
✅ Windows 10, version 20H2 with KB5005101 [10.0.19042.1202] and later
✅ Windows 10, version 21H1 with KB5005101 [10.0.19043.1202] and later
✅ Windows 11, version 21H2 [10.0.22000] and later
./Device/Vendor/MSFT/Policy/Config/ADMX_WinInit/ShutdownTimeoutHungSessionsDescription

This policy setting configures the number of minutes the system waits for the hung logon sessions before proceeding with the system shutdown.

  • If you enable this policy setting, the system waits for the hung logon sessions for the number of minutes specified.

  • If you disable or don't configure this policy setting, the default timeout value is 3 minutes for workstations and 15 minutes for servers.

Description framework properties:

Property name Property value
Format chr (string)
Access Type Add, Delete, Get, Replace

[!INCLUDE ADMX-backed policy note]

ADMX mapping:

Name Value
Name ShutdownTimeoutHungSessionsDescription
Friendly Name Timeout for hung logon sessions during shutdown
Location Computer Configuration
Path Windows Components > Shutdown Options
Registry Key Name Software\Microsoft\Windows\CurrentVersion\Policies\System
ADMX File Name WinInit.admx

Related articles