Notifications
You must be signed in to change notification settings - Fork 32.5k
/
Copy pathclimate.py
205 lines (181 loc) · 7.04 KB
/
climate.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
"""Platform for Flexit AC units with CI66 Modbus adapter."""
from __future__ import annotations
import logging
from typing import Any
import voluptuous as vol
from homeassistant.components.climate import (
PLATFORM_SCHEMA as CLIMATE_PLATFORM_SCHEMA,
ClimateEntity,
ClimateEntityFeature,
HVACAction,
HVACMode,
)
from homeassistant.components.modbus import (
CALL_TYPE_REGISTER_HOLDING,
CALL_TYPE_REGISTER_INPUT,
DEFAULT_HUB,
ModbusHub,
get_hub,
)
from homeassistant.const import (
ATTR_TEMPERATURE,
CONF_NAME,
CONF_SLAVE,
DEVICE_DEFAULT_NAME,
UnitOfTemperature,
)
from homeassistant.core import HomeAssistant
import homeassistant.helpers.config_validation as cv
from homeassistant.helpers.entity_platform import AddEntitiesCallback
from homeassistant.helpers.typing import ConfigType, DiscoveryInfoType
CALL_TYPE_WRITE_REGISTER = "write_register"
CONF_HUB = "hub"
PLATFORM_SCHEMA = CLIMATE_PLATFORM_SCHEMA.extend(
{
vol.Optional(CONF_HUB, default=DEFAULT_HUB): cv.string,
vol.Required(CONF_SLAVE): vol.All(int, vol.Range(min=0, max=32)),
vol.Optional(CONF_NAME, default=DEVICE_DEFAULT_NAME): cv.string,
}
)
_LOGGER = logging.getLogger(__name__)
async def async_setup_platform(
hass: HomeAssistant,
config: ConfigType,
async_add_entities: AddEntitiesCallback,
discovery_info: DiscoveryInfoType | None = None,
) -> None:
"""Set up the Flexit Platform."""
modbus_slave = config.get(CONF_SLAVE)
name = config.get(CONF_NAME)
hub = get_hub(hass, config[CONF_HUB])
async_add_entities([Flexit(hub, modbus_slave, name)], True)
class Flexit(ClimateEntity):
"""Representation of a Flexit AC unit."""
_attr_fan_modes = ["Off", "Low", "Medium", "High"]
_attr_hvac_mode = HVACMode.COOL
_attr_hvac_modes = [HVACMode.COOL]
_attr_supported_features = (
ClimateEntityFeature.TARGET_TEMPERATURE | ClimateEntityFeature.FAN_MODE
)
_attr_temperature_unit = UnitOfTemperature.CELSIUS
def __init__(
self, hub: ModbusHub, modbus_slave: int | None, name: str | None
) -> None:
"""Initialize the unit."""
self._hub = hub
self._attr_name = name
self._slave = modbus_slave
self._attr_fan_mode = None
self._filter_hours: int | None = None
self._filter_alarm: int | None = None
self._heat_recovery: int | None = None
self._heater_enabled: int | None = None
self._heating: int | None = None
self._cooling: int | None = None
self._alarm = False
self._outdoor_air_temp: float | None = None
async def async_update(self) -> None:
"""Update unit attributes."""
self._attr_target_temperature = await self._async_read_temp_from_register(
CALL_TYPE_REGISTER_HOLDING, 8
)
self._attr_current_temperature = await self._async_read_temp_from_register(
CALL_TYPE_REGISTER_INPUT, 9
)
res = await self._async_read_int16_from_register(CALL_TYPE_REGISTER_HOLDING, 17)
if self.fan_modes and res < len(self.fan_modes):
self._attr_fan_mode = self.fan_modes[res]
self._filter_hours = await self._async_read_int16_from_register(
CALL_TYPE_REGISTER_INPUT, 8
)
# # Mechanical heat recovery, 0-100%
self._heat_recovery = await self._async_read_int16_from_register(
CALL_TYPE_REGISTER_INPUT, 14
)
# # Heater active 0-100%
self._heating = await self._async_read_int16_from_register(
CALL_TYPE_REGISTER_INPUT, 15
)
# # Cooling active 0-100%
self._cooling = await self._async_read_int16_from_register(
CALL_TYPE_REGISTER_INPUT, 13
)
# # Filter alarm 0/1
self._filter_alarm = await self._async_read_int16_from_register(
CALL_TYPE_REGISTER_INPUT, 27
)
# # Heater enabled or not. Does not mean it's necessarily heating
self._heater_enabled = await self._async_read_int16_from_register(
CALL_TYPE_REGISTER_INPUT, 28
)
self._outdoor_air_temp = await self._async_read_temp_from_register(
CALL_TYPE_REGISTER_INPUT, 11
)
actual_air_speed = await self._async_read_int16_from_register(
CALL_TYPE_REGISTER_INPUT, 48
)
if self._heating:
self._attr_hvac_action = HVACAction.HEATING
elif self._cooling:
self._attr_hvac_action = HVACAction.COOLING
elif self._heat_recovery:
self._attr_hvac_action = HVACAction.IDLE
elif actual_air_speed:
self._attr_hvac_action = HVACAction.FAN
else:
self._attr_hvac_action = HVACAction.OFF
@property
def extra_state_attributes(self) -> dict[str, Any]:
"""Return device specific state attributes."""
return {
"filter_hours": self._filter_hours,
"filter_alarm": self._filter_alarm,
"heat_recovery": self._heat_recovery,
"heating": self._heating,
"heater_enabled": self._heater_enabled,
"cooling": self._cooling,
"outdoor_air_temp": self._outdoor_air_temp,
}
async def async_set_temperature(self, **kwargs: Any) -> None:
"""Set new target temperature."""
if (target_temperature := kwargs.get(ATTR_TEMPERATURE)) is None:
_LOGGER.error("Received invalid temperature")
return
if await self._async_write_int16_to_register(8, int(target_temperature * 10)):
self._attr_target_temperature = target_temperature
else:
_LOGGER.error("Modbus error setting target temperature to Flexit")
async def async_set_fan_mode(self, fan_mode: str) -> None:
"""Set new fan mode."""
if self.fan_modes and await self._async_write_int16_to_register(
17, self.fan_modes.index(fan_mode)
):
self._attr_fan_mode = fan_mode
else:
_LOGGER.error("Modbus error setting fan mode to Flexit")
# Based on _async_read_register in ModbusThermostat class
async def _async_read_int16_from_register(
self, register_type: str, register: int
) -> int:
"""Read register using the Modbus hub slave."""
result = await self._hub.async_pb_call(self._slave, register, 1, register_type)
if result is None:
_LOGGER.error("Error reading value from Flexit modbus adapter")
return -1
return int(result.registers[0])
async def _async_read_temp_from_register(
self, register_type: str, register: int
) -> float:
result = float(
await self._async_read_int16_from_register(register_type, register)
)
if not result:
return -1
return result / 10.0
async def _async_write_int16_to_register(self, register: int, value: int) -> bool:
result = await self._hub.async_pb_call(
self._slave, register, value, CALL_TYPE_WRITE_REGISTER
)
if not result:
return False
return True