Notifications
You must be signed in to change notification settings - Fork 97
1.8.1b21 External temp #160
Comments
With 1.8.0 info reports: Not present in 1.8.1b21... |
Running the b21 I always get the outdoor temp.
Can you post a log - about 5min in length?
Von meinem iPad gesendet
… Am 21.07.2019 um 17:34 schrieb Sonusss ***@***.***>:
With 1.8.0 info reports:
Outside temperature: 26.3 C
Not present in 1.8.1b21...
—
You are receiving this because you are subscribed to this thread.
Reply to this email directly, view it on GitHub, or mute the thread.
|
I just need a few UBAMonitorSlow (type 0x19) to debug. The outdoor temp is in the first 2 bytes of the data part. |
My system have UBAMonitorFast(0x18)... System Logging set to Verbose |
the problem was that 0x19 wasn't being picked up because of the buffer size was 32 and not 33 bytes. Anyway, should be fixed in 1.8.1b23 |
My boiler have external temp probe.
It is not reported anymore nor MQTT or telnet info
It was working in 1.8.0
The text was updated successfully, but these errors were encountered: