Random notes about Z-Wave to remember for later.

root@rpi# docker run --restart always -d -p 8091:8091 -p 3000:3000 --device=/dev/ttyAMA0 --mount source=zwavejs2mqtt,target=/usr/src/app/store zwavejs/zwavejs2mqtt:latest

Review setup instructions

Note: device is ttyAMA0

Updating zwavejs2mqtt

root@rpi# docker pull zwavejs/zwavejs2mqtt
root@rpi# docker ps
root@rpi# docker stop [container_id]
root@rpi# docker rm [container_id]
root@rpi# docker run --restart always -d -p 8091:8091 -p 3000:3000 --device=/dev/ttyAMA0 --mount source=zwavejs2mqtt,target=/usr/src/app/store zwavejs/zwavejs2mqtt:latest
root@rpi# docker image rm [old image]

Aeon Labs by Aeotec "Smart Strip" DSC11-ZWUS

The device has six outlets, two always on and four controlled by Z-Wave. It also provides energy monitoring. However, as reported the Z-Wave instances don't line up with the physical device.

Physical Outlet Z-Wave Switch Instance Z-Wave Sensor instance HA entity Notes
Always on 1 n/a 1 Next to action button
Always on 2 n/a 2
Switchable 1 1 3
Switchable 2 2 4
Switchable 3 3 n/a
Switchable 4 4 n/a

As reported by ZwaveJS to Home Assistant.

Devices that require polling

  • all remotec switches for the lawn

Fakro skylight notes

Per email with Fakro support on 12/3/19 If the window is closed, it always reports Value 0, even if it is raining

If the window is open

  • Value 0 - occurs only after the first answer since the power reset - when the rain sensor does not detect
  • Value 1 - reports when the sensor is active (rain detection occurs)
  • Value 254 - reports when the sensor is not detecting rain at a given moment - i.e. when it is not raining