Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
Here is my simulation, designed to interpret a DICOM RT plan and execute a photon beam irradiation on a patient in accordance with the specified plan.
To validate the functionality, I randomly selected four Control Points from the RT-plan. Subsequently, I computed the theoretical area generated by the collimation system aperture. To validate the built simulation, I simulated an alpha source at 1 MeV in a vacuum, determining its passage (or obstruction) through the collimation system before its interception in the first water voxel encountered within the simulated water tank. This simulation enables a direct comparison between the theoretically calculated area and the simulated area, derived from the summation of voxel areas triggered by the alpha beam. A predefined tolerance of 8% has been established to gauge the similarity between the two resulting areas.