Notifications
You must be signed in to change notification settings - Fork 2.1k
/
Copy pathTC_EEVSE_2_5.py
192 lines (158 loc) · 8.99 KB
/
TC_EEVSE_2_5.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
#
# Copyright (c) 2023 Project CHIP Authors
# All rights reserved.
#
# Licensed under the Apache License, Version 2.0 (the "License");
# you may not use this file except in compliance with the License.
# You may obtain a copy of the License at
#
# http://www.apache.org/licenses/LICENSE-2.0
#
# Unless required by applicable law or agreed to in writing, software
# distributed under the License is distributed on an "AS IS" BASIS,
# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
# See the License for the specific language governing permissions and
# limitations under the License.
# See https://github.com/project-chip/connectedhomeip/blob/master/docs/testing/python.md#defining-the-ci-test-arguments
# for details about the block below.
#
# === BEGIN CI TEST ARGUMENTS ===
# test-runner-runs:
# run1:
# app: ${ENERGY_MANAGEMENT_APP}
# app-args: >
# --discriminator 1234
# --KVS kvs1
# --trace-to json:${TRACE_APP}.json
# --enable-key 000102030405060708090a0b0c0d0e0f
# --application evse
# script-args: >
# --storage-path admin_storage.json
# --commissioning-method on-network
# --discriminator 1234
# --passcode 20202021
# --hex-arg enableKey:000102030405060708090a0b0c0d0e0f
# --endpoint 1
# --trace-to json:${TRACE_TEST_JSON}.json
# --trace-to perfetto:${TRACE_TEST_PERFETTO}.perfetto
# factory-reset: true
# quiet: true
# === END CI TEST ARGUMENTS ===
import logging
import chip.clusters as Clusters
from chip.clusters.Types import NullValue
from chip.interaction_model import Status
from chip.testing.matter_testing import EventChangeCallback, MatterBaseTest, TestStep, async_test_body, default_matter_test_main
from TC_EEVSE_Utils import EEVSEBaseTestHelper
logger = logging.getLogger(__name__)
class TC_EEVSE_2_5(MatterBaseTest, EEVSEBaseTestHelper):
def desc_TC_EEVSE_2_5(self) -> str:
"""Returns a description of this test"""
return "5.1.6. [TC-EEVSE-2.5] Optional diagnostics functionality with DUT as Server"
def pics_TC_EEVSE_2_5(self):
""" This function returns a list of PICS for this test case that must be True for the test to be run"""
# In this case - we need the EVSE to support the StartDiagnostics command
return ["EEVSE.S", "EEVSE.S.C04.Rsp"]
def steps_TC_EEVSE_2_5(self) -> list[TestStep]:
steps = [
TestStep("1", "Commission DUT to TH (can be skipped if done in a preceding test)",
is_commissioning=True),
TestStep("2", "TH reads TestEventTriggersEnabled attribute from General Diagnostics Cluster",
"Value has to be 1 (True)"),
TestStep("3", "TH sends TestEventTrigger command to General Diagnostics Cluster on Endpoint 0 with EnableKey field set to PIXIT.EEVSE.TESTEVENT_TRIGGERKEY and EventTrigger field set to PIXIT.EEVSE.TESTEVENTTRIGGER for Basic Functionality Test Event",
"Verify DUT responds w/ status SUCCESS(0x00)"),
TestStep("3a", "TH reads from the DUT the State",
"Value has to be 0x00 (NotPluggedIn)"),
TestStep("3b", "TH reads from the DUT the SupplyState",
"Value has to be 0x00 (Disabled)"),
TestStep("3c", "TH reads from the DUT the FaultState",
"Value has to be 0x00 (NoError)"),
TestStep("4", "TH sends command EnableCharging with ChargingEnabledUntil=null, minimumChargeCurrent=6000, maximumChargeCurrent=60000",
"Verify DUT responds w/ status SUCCESS(0x00)"),
TestStep("4a", "TH reads from the DUT the State",
"Value has to be 0x00 (NotPluggedIn)"),
TestStep("4b", "TH reads from the DUT the SupplyState",
"Value has to be 0x01 (ChargingEnabled)"),
TestStep("5", "TH sends command StartDiagnostics",
"Verify DUT responds w/ status FAILURE(0x01)"),
TestStep("6", "TH sends command Disable",
"Verify DUT responds w/ status SUCCESS(0x00)"),
TestStep("6a", "TH reads from the DUT the State",
"Value has to be 0x00 (NotPluggedIn)"),
TestStep("6b", "TH reads from the DUT the SupplyState",
"Value has to be 0x00 (Disabled)"),
TestStep("7", "TH sends command StartDiagnostics",
"Verify DUT responds w/ status SUCCESS(0x00)"),
TestStep("7a", "TH reads from the DUT the SupplyState",
"Value has to be 0x04 (DisabledDiagnostics)"),
TestStep("8", "TH sends command EnableCharging with ChargingEnabledUntil=null, minimumChargeCurrent=6000, maximumChargeCurrent=60000",
"Verify DUT responds w/ status FAILURE(0x01)"),
TestStep("8a", "TH reads from the DUT the SupplyState",
"Value has to be 0x04 (DisabledDiagnostics)"),
TestStep("9", "TH sends TestEventTrigger command to General Diagnostics Cluster on Endpoint 0 with EnableKey field set to PIXIT.EEVSE.TESTEVENT_TRIGGERKEY and EventTrigger field set to PIXIT.EEVSE.TESTEVENTTRIGGER for EVSE Diagnostics Complete Event",
"Verify DUT responds w/ status SUCCESS(0x00)"),
TestStep("9a", "TH reads from the DUT the State",
"Value has to be 0x00 (NotPluggedIn)"),
TestStep("9b", "TH reads from the DUT the SupplyState",
"Value has to be 0x00 (Disabled)"),
TestStep("10", "TH sends TestEventTrigger command to General Diagnostics Cluster on Endpoint 0 with EnableKey field set to PIXIT.EEVSE.TESTEVENT_TRIGGERKEY and EventTrigger field set to PIXIT.EEVSE.TESTEVENTTRIGGER for Basic Functionality Test Event Clear",
"Verify DUT responds w/ status SUCCESS(0x00)"),
]
return steps
@async_test_body
async def test_TC_EEVSE_2_5(self):
self.step("1")
# Commission DUT - already done
# Subscribe to Events and when they are sent push them to a queue for checking later
events_callback = EventChangeCallback(Clusters.EnergyEvse)
await events_callback.start(self.default_controller,
self.dut_node_id,
self.get_endpoint())
self.step("2")
await self.check_test_event_triggers_enabled()
self.step("3")
await self.send_test_event_trigger_basic()
self.step("3a")
await self.check_evse_attribute("State", Clusters.EnergyEvse.Enums.StateEnum.kNotPluggedIn)
self.step("3b")
await self.check_evse_attribute("SupplyState", Clusters.EnergyEvse.Enums.SupplyStateEnum.kDisabled)
self.step("3c")
await self.check_evse_attribute("FaultState", Clusters.EnergyEvse.Enums.FaultStateEnum.kNoError)
self.step("4")
charge_until = NullValue
min_charge_current = 6000
max_charge_current = 60000
await self.send_enable_charge_command(charge_until=charge_until, min_charge=min_charge_current, max_charge=max_charge_current)
self.step("4a")
await self.check_evse_attribute("State", Clusters.EnergyEvse.Enums.StateEnum.kNotPluggedIn)
self.step("4b")
await self.check_evse_attribute("SupplyState", Clusters.EnergyEvse.Enums.SupplyStateEnum.kChargingEnabled)
self.step("5")
# Check we get a failure because the state needs to be Disabled to run a Diagnostic
await self.send_start_diagnostics_command(expected_status=Status.Failure)
self.step("6")
await self.send_disable_command()
self.step("6a")
await self.check_evse_attribute("State", Clusters.EnergyEvse.Enums.StateEnum.kNotPluggedIn)
self.step("6b")
await self.check_evse_attribute("SupplyState", Clusters.EnergyEvse.Enums.SupplyStateEnum.kDisabled)
self.step("7")
await self.send_start_diagnostics_command()
self.step("7a")
await self.check_evse_attribute("SupplyState", Clusters.EnergyEvse.Enums.SupplyStateEnum.kDisabledDiagnostics)
self.step("8")
await self.send_enable_charge_command(charge_until=charge_until, min_charge=min_charge_current,
max_charge=max_charge_current, expected_status=Status.Failure)
self.step("8a")
await self.check_evse_attribute("SupplyState", Clusters.EnergyEvse.Enums.SupplyStateEnum.kDisabledDiagnostics)
self.step("9")
await self.send_test_event_trigger_evse_diagnostics_complete()
self.step("9a")
await self.check_evse_attribute("State", Clusters.EnergyEvse.Enums.StateEnum.kNotPluggedIn)
self.step("9b")
# It should stay disabled after a diagnostics session
await self.check_evse_attribute("SupplyState", Clusters.EnergyEvse.Enums.SupplyStateEnum.kDisabled)
self.step("10")
await self.send_test_event_trigger_basic_clear()
if __name__ == "__main__":
default_matter_test_main()